The heating panel is the patented Thermal Power 100% Radiant "Luminous Wall" (LPG fueled).
A. Controllability so as to instantly and evenly spread up to 100,000 BTU' per square foot in a 66 square foot area.
B. The 6' x 13' instant ON-OFF heating panel is divided into four zones. Individually controlled to heat in widths in any combination to make the following widths of 2-1/2' 4', 6-1/2', 8', 10-1/2' or 13'.
C. The heating panel is fueled by LPG and has a BTU/hr. Output of the following:
Zones 1 and
4................................................... 1,266,000 BTU/hr.
each
Zones 2 and
3 ...................................................2,134,000 BTU/hr.
each
Total BTU/hr.
output .........................................6,800.000 BTU/hr.
D. The mounting has a tilt range of 90 degrees horizontal to vertical. The wings are hinged to manually tilt 90 degrees for a total transport width of 8';6".
E. All piping, ducting, fittings and accessories such as: gas/air mixers, solenoid valves, limiting orifice valves, blowers, etc., are sized and installed to properly insure the maximum operating efficiency of the "Luminous Wall" heating panel system.
Hydraulic System
Flow through with operating pressures of 2,000 PSI having a capacity of 37 gallons.
Controls
A. Hydraulic system is operated by 12-volt D.C. electric solenoid valve controls, which includes push buttons to operate the movement of the heating panel and hydraulic options mounted inside the cab easily controlled by the operator.
B. The heating panel controls are mounted on the same instrument panel as the hydraulic control. The heating panel controls are powered by 12 volt D.C. with power off safety inter-locked design. They have four individual ON/OFF switches and indicator lights for each zone with a pushbutton master start/stop switch. The control panel is equipped with indicator lights as follows:
Four Zone Lights ........Amber
Power-On ...................Red
Air Pressure................Green
Safety Light ...............Green
Safety Switches for Heating Panel
In addition to the pushbutton master switch mounted on the control panel, additional safety switches are mounted on each side of the unit.
Power Plant
35 hp, 4 cycle, 3200 RPM electric start, 12-volt D.C. 15 amp alternator system power by LPG.
Truck Power Plant
The cab and chassis used on this model shall be a minimum of 170 hp, 5-speed transmission with a 20,000 lb. rear and 9,000 lb. front axel.
LPG Fuel Tank
500 U.S. gallon capacity equipped for liquid and vapor withdrawal.
Vaporizer
80 U.S. gallons per hour.
Frame
Electric arc welded structural steel including skirting around the wheel wells. Flexible heat deflectors mounted on the rear of the truck.
OPTION SPECIFICATIONS
Low Speed Control
Transverse case powered by a hydraulic motor powered by a PTO altering the travel speed from 2 FPM to 65 MPH.
Hydraulic Side Shift
The wall can be hydraulically shifted left/right 24".
Hydraulic Raise and Lower Wall
The wall can be hydraulically raised or lowered 6" to adjust for various weights due to LPG use, keeping the wall at a constant distance from the pavement.
Hydraulic Tilt Wings
Wings hydraulically tilt 90 degrees horizontal to vertical for traveling or working position.
Soaking Pans
A. Attached to the "Luminous Wall" heating panel is a 4' x 13' highly insulated soaking pan divided into 4 zones.
Zones 1 and 4 ...............................................................4' x
2' each
Zones 2 and 3................................................................4' x
4' each
Full size soaking area ..................................................52
sq. ft.
B. Made of electrically arc welded 3/16" steel.
C. The Mounting has a hydraulic
tilt range of 90 degrees horizontal to vertical, wings
hinging 90 degrees, to be
folded for a total traveling width of 8'6".
Second LPG Tank
A second 500 gallon LPG tank equipped for liquid and vapor withdrawal.
Tool Boxes
Tool Boxes located on both sides of the unit between the rear wheels and the cab.
PTO Overspeed
Chelsea or equal power take-off available for automatic transmissions with electric over hydraulic controls to prevent damage to the hydraulic pump due to high RPM's.
Strobe Light
Lear-Siegler model 6850,
12 volt D.C. or equal.
THERMAL POWER INC. IS PROUD TO BE THE
WORLD LEADER IN PAVEMENT RECYCLING EQUIPMENT AND METHODS. THEREFORE, RESERVES
THE RIGHT TO MAKE ANY DESIGN, MATERIAL, AND/OR SPECIFICATION CHANGES WITHOUT
NOTICE.
Call Us Toll Free in the USA & Canada: 800-677-9442